Water Cooled Chiller
Water cooled Screw Chiller Series
Views:3826   Updated:2014/7/5 11:10:01


SCREW CHILLERS                          

Cooling only

Heating- recovery

Total heat recovery

Capacity: 110÷3800 KW

RefrigerantR134a R22

High energy efficiencyFlooded type exchanger


FEATURES

• 20 sizes available ranging from 110kW to 3800kW cooling capacity.

• Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.

• Hermetic scroll compressor and semi-hermetic screw compressor, each compressor is equipped with a crankcase heater and a thermal overload cut-out,the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.

• The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.

• Shell and tube dry expansion type condenser, factory insulated with flexible close cell material.

• The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.

• LCD display, touch screen control panel as standard.

• Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

• For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the requirement of the system. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.

Optional

• Electronic expansion valve.

• Electronic controller with BMS system.

Model

 

LSBLG210

LSBLG310

LSBLG400

LSBLG450

LSBLG530

Nominal cooling capacity

KW

210

311

402

450

534

104kcal/h

18.06

26.75

34.57

38.70

45.92

Rt

60

88

114

128

152

Total power input

KW

42

62

80

90

107

Start current

A

580

870

1130

1270

1510

Max. running current

A

100

160

200

230

280

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

25% startup, 50%~100%, stepless capacity control

Safe protection

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressor(R22)

quantity

set

one

startup type

 

Y-Δ

input power

kw

44.5

65.8

85.2

96.2

112

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

36.1

53.5

69.1

77.4

91.8

water resistance

kPa

50

52

54

54

58

water inlet/outlet pipe diameter

mm

DN80

DN100

DN100

DN125

DN125

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

43.8

64.8

83.8

93.9

111.1

water resistance

kPa

58

60

60

60

62

water inlet/outlet pipe diameter

mm

DN80

DN100

DN100

DN125

DN125

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

2950

3180

3200

3200

3300

width

mm

1050

1050

1165

1165

1210

height

mm

1450

1450

1670

1670

1725

Refrigerant charge

kg

41

67

80

97

120

Refrigeration system (circuit quantity)

1

Refrigeration control method

Thermostatic expansion valve

Noise level

DB/(A)

65

66

68

70

72

Net weight

kg

1370

1450

1780

1952

2150

Running weight

kg

1500

1650

1958

2147

2430

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR22

Model

 

LSBLG650

LSBLG690

LSBLG750

LSBLG810

LSBLG870

Nominal cooling capacity

KW

652

690

751

813

870

104kcal/h

56.07

59.34

64.59

69.92

74.82

Rt

185

196

214

231

247

Total power input

KW

130

138

150

163

174

Start current

A

1830

1950

2100

2300

2460

Max. running current

A

340

360

400

430

450

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

25% startup, 50%~100%, stepless capacity control

Safe protection

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressor(R22)

quantity

set

one

startup type

 

Y-Δ

input power

kw

137.2

145.8

158.5

172.2

179.7

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

112.1

118.7

129.2

139.8

149.6

water resistance

kPa

63

66

70

80

80

water inlet/outlet pipe diameter

mm

DN150

DN150

DN150

DN150

DN150

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

135.7

143.8

156.4

169.5

180.6

water resistance

kPa

63

63

63

63

63

water inlet/outlet pipe diameter

mm

DN150

DN150

DN150

DN150

DN150

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

3550

3550

3600

3600

3700

width

mm

1235

1235

1235

1470

1590

height

mm

1745

1810

1810

1860

2020

Refrigerant charge

kg

126

133

135

145

151

Refrigeration system (circuit quantity)

1

Refrigeration control method

Thermostatic expansion valve

Noise level

DB/(A)

73

73

73

75

76

Net weight

kg

2650

2860

3220

3350

3510

Running weight

kg

3200

3420

3650

3950

4120

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR22

Model

 

 

 

 

 

 

 

Nominal cooling capacity

KW

1154

1302

1500

1622

1750

104kcal/h

99.24

111.97

129.00

139.49

150.50

Rt

328

370

426

461

498

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

 

12.5% startup, 25%~100%, stepless capacity control

Safe protection

 

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressorR22

quantity

set

2

2

2

2

4

startup type

 

Y-Δ

input power

 

235.2

266.4

296.6

325.8

353.2

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

198.5

223.9

258

279

301

water resistance

kPa

80

82

85

85

95

water inlet/outlet pipe diameter

DN

200

200

200

200

200

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

238.9

269.8

309

335

361.8

water resistance

kPa

66

66

66

67

67

water inlet/outlet pipe diameter

DN

125*2

150*2

150*2

150*2

150*2

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

4380

4500

4580

4750

4950

width

mm

1500

1550

1550

1650

1670

height

mm

2200

2200

2300

2300

2350

Refrigeration system (circuit quantity)

 

2

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

73

73

75

76

77

Net weight

kg

4500

4710

5100

5630

6120

Running weight

kg

5050

5190

5500

6100

6800

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR22

Model

 

 

 

 

 

 

 

Nominal cooling capacity

KW

2100

2602

2981

3249

3800

104kcal/h

180.60

223.77

256.37

279.41

326.80

Rt

597

740

848

924

1080

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

 

12.5% startup, 25%~100%, stepless capacity control

Safe protection

 

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressorR22

quantity

set

4

4

4

4

4

startup type

 

Y-Δ

input power

 

428.5

525.6

585

652.4

749

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

361.2

447.5

512.5

558.8

653.6

water resistance

kPa

95

97

98

98

98

water inlet/outlet pipe diameter

DN

250

250

300

300

300

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

434.9

538

613.4

671

782.4

water resistance

kPa

68

68

70

70

70

water inlet/outlet pipe diameter

DN

150*4

150*4

150*4

150*4

150*4

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

4300

4500

4580

4800

4950

width

mm

2750

3100

3180

3250

3250

height

mm

2250

2250

2300

2380

2500

Refrigeration system (circuit quantity)

 

2

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

79

79

80

81

81

Net weight

kg

8350

9450

11200

12000

12800

Running weight

kg

9050

11350

12500

13200

14100

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR134a

Model

 

 

 

 

 

 

 

Nominal cooling capacity

KW

110

171

210

262

293

355

104kcal/h

9.46

14.71

18.06

22.53

25.20

30.53

Rt

31

49

60

74

83

101

Total power input

KW

22

34

42

52

58

71

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

 

25% startup, 50%~100%, stepless capacity control

Safe protection

 

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressor(R134a)

quantity

set

one

startup type

 

Y-Δ

input power

kw

26.2

41.5

50.2

61.8

67.5

83.1

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

18.9

29.4

36.1

45.1

50.4

61.1

water resistance

kPa

50

52

54

54

58

60

water inlet/outlet pipe diameter

DN

80

100

100

100

100

125

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

23.4

36.6

44.8

55.7

62

75.4

water resistance

kPa

58

60

60

60

62

63

water inlet/outlet pipe diameter

DN

80

100

100

100

100

125

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

2700

2900

3100

3100

3180

3200

width

mm

1050

1050

1050

1050

1050

1165

height

mm

1450

1450

1450

1450

1450

1670

Refrigeration system (circuit quantity)

 

1

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

65

66

68

70

72

73

Net weight

kg

1310

1480

1570

1770

1870

2100

Running weight

kg

1420

1580

1660

1880

1980

2240

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR134a

Model

 

 

 

 

 

 

Nominal cooling capacity

KW

420

480

528

560

631

104kcal/h

36.12

41.28

45.41

48.16

54.27

Rt

119

136

150

159

179

Total power input

KW

84

96

106

112

126

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

 

25% startup, 50%~100%, stepless capacity control

Safe protection

 

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressor(R134a)

quantity

set

one

startup type

 

Y-Δ

input power

kw

94.5

106.8

115.2

122.5

147.8

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

72.2

82.6

90.8

96.3

108.5

water resistance

kPa

60

61

61

62

68

water inlet/outlet pipe diameter

DN

125

150

150

150

150

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

88.5

100.9

110.6

117.4

134

water resistance

kPa

63

63

64

64

64

water inlet/outlet pipe diameter

DN

125

150

150

150

100*2

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

3300

3300

3550

3600

4300

width

mm

1210

1210

1235

1235

1480

height

mm

1725

1725

1810

1810

2100

Refrigeration system (circuit quantity)

 

1

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

73

73

75

76

73

Net weight

kg

2570

2880

3150

3250

4020

Running weight

kg

2820

3070

3480

3550

4350

 

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR134a

Model

 

 

 

 

 

 

 

Nominal cooling capacity

KW

714

770

840

900

960

1060

104kcal/h

61.40

66.22

72.24

77.40

82.56

91.16

Rt

203

219

239

256

273

301

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

12.5% startup, 25%~100%, stepless capacity control

Safe protection

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressorR134a

quantity

set

2

2

2

2

2

2

startup type

 

Y-Δ

input power

 

165.5

177.4

194.6

207.8

220.6

238.2

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

122.8

132.4

144.5

154.8

165.1

182.3

water resistance

kPa

66

66

67

67

68

68

water inlet/outlet pipe diameter

DN

125*2

125*2

125*2

125*2

125*2

125*2

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

151.3

163

178

190.5

203.1

223.3

water resistance

kPa

66

66

67

67

68

68

water inlet/outlet pipe diameter

DN

150

150

150

150

150

200

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

4300

4400

4500

4700

4750

4900

width

mm

1500

1500

1500

1550

1600

1650

height

mm

2100

2100

2100

2200

2200

2300

Refrigeration system (circuit quantity)

 

2

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

73

75

76

77

77

77

Net weight

kg

4210

4320

4580

4870

5210

5640

Running weight

kg

4520

4770

4950

5300

5620

6020

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.

TECHNICAL DATAR134a 

Model

 

 

 

 

 

 

 

Nominal cooling capacity

KW

1122

1420

1680

1920

2120

2251

104kcal/h

96.49

122.12

144.48

165.12

182.32

193.59

Rt

319

404

478

546

603

640

Power supply

 

3N~, AC380V, 50Hz

Running control method

 

Programmable logistic control, fully automation

Appearance colour

 

white

Capacity control range

12.5% startup, 25%~100%, stepless capacity control

Safe protection

water-lackage delay protection,high and low pressure switch, freeze protection device, overheat protection, overload protection device,phase sequence and short of phase protection, safety valve

Compressor

type

 

semi-hermetic twin screws compressorR134a

quantity

set

2

4

4

4

4

4

startup type

 

 

 

 

 

 

 

input power

 

248.5

331.2

388.5

441.7

477.3

501.8

Evaporator

type

 

shell&tube, designed permitted pressure: 1.4MPa

water flow range

m3/h

193

244.2

289

330.2

364.6

387.2

water resistance

kPa

68

68

69

70

70

70

water inlet/outlet pipe diameter

DN

125*2

125*4

125*4

125*4

125*4

125*4

evaporator water drain pipe

mm

Rc1/2"

insulation material

 

NBR-PVC

Condenser

type

 

shell&tube, designed permitted pressure: 1.9MPa

water flow range

m3/h

235.7

301.2

355.8

406.2

446.7

473.5

water resistance

kPa

68

68

69

70

70

70

water inlet/outlet pipe diameter

DN

200

200

200

250

250

250

conderser water drain pipe

mm

Rc1/2"

External dimension

length

mm

5000

4500

4580

4800

4800

5000

width

mm

1670

3100

3100

3250

3250

3250

height

mm

2350

2250

2250

2300

2380

2500

Refrigeration system (circuit quantity)

 

2

Refrigeration control method

 

Thermostatic expansion valve

Noise level

DB/(A)

78

78

80

81

81

81

Net weight

kg

6150

8540

9320

10450

11600

12870

Running weight

kg

6520

9100

9860

11050

12200

13700

Nominal working condition:chilled water inlet/outlet temp. 12/7℃, cooling water inlet/outlet temp. 32/37℃, fouling factor:0.086m2 ℃/KW

If you need the unit with the evaporator or condenser whose permitted pressure is more than 1.4/1.9MPa, please contact with us

The capacity control type can be stepless one.If you need, please confirm this point in the technical requirement.Its control range is 25%~100%.                                                                                        

The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. The noise level is measured at 2meter in front of the unit, 2 meter high to the ground.


<<<<<< Previous:Water Source Modular Scroll Heat Pump              Next:none >>>>>>
ALK Air Conditioning (c) Copyright 2020 Group Email